Changes between Version 1 and Version 2 of Hand/280/Supervisory


Ignore:
Timestamp:
May 17, 2011, 8:41:50 PM (14 years ago)
Author:
edison
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • Hand/280/Supervisory

    v1 v2  
    55The BH8-280 hand implements each of the important commands found in the earlier BH8-Series hands to offer compatibility.  These commands are found in the new hand:
    66
    7 •       Movement commands: C, HI, HOME, IO, IC, LOOP, M, O, T, TC, TO
    8 •       Motor property commands: FSET, FGET, FLOAD, FSAVE, FDEF
    9 •       Global property commands: PSET*, PGET*
    10 •       Administrative commands: RESET
     7 * Movement commands: C, HI, HOME, IO, IC, LOOP, M, O, T, TC, TO
     8 * Motor property commands: FSET, FGET, FLOAD, FSAVE, FDEF
     9 * Global property commands: PSET*, PGET*
     10 * Administrative commands: RESET
    1111
    1212Note that PSET and PGET are commands for setting and getting global property values.  The 280 hand will set all properties to the given value for PSET commands and will return -9 for a PGET command.  The API does contain some virtual properties like the global “LFT” loop feedback temperature property.  Virtual properties are read and written to variables on the host PC.  The following commands have been left out for the 280 hand and probably won't be available because there is no interactive mode via command prompt or global properties.
    1313
    14 •       Motor property commands: FLIST, FLISTV
    15 •       Global property commands: PLOAD*, PSAVE*, PDEF, PLIST, PLISTV
    16 •       Global property commands:
    17 •       Administrative commands: ?, ERR, VERS
    18 •       Advanced commands: a?, FLISTA, FLISTAV, PLISTA, PLISTAV
     14 * Motor property commands: FLIST, FLISTV
     15 * Global property commands: PLOAD*, PSAVE*, PDEF, PLIST, PLISTV
     16 * Global property commands:
     17 * Administrative commands: ?, ERR, VERS
     18 * Advanced commands: a?, FLISTA, FLISTAV, PLISTA, PLISTAV
    1919
    2020The hand API provides a special “Command” method for processing a subset of the Grasper Control Language (GCL) character strings containing commands and returns a response to commands in a user supplied receive buffer.  The string is parsed into commands that may contain a motor string prefix and possibly some parameters.  This allows significant backwards compatibility and allows sending commands in the form of strings and receiving responses from the hand in the form of a string.  A list of the presently accepted strings include “RESET” and:
    2121
    22 •       “HI”
    23 •       “C”, “O”
    24 •       “M <optional position parameter>”
    25 •       “HOME”
    26 •       “IC <optional step size parameter>”, “IO <optional step size parameter>”
    27 •       “TC”, “TO”
    28 •       “FSET <property> <value>”
    29 •       “FGET <property>”
    30 •       “FLOAD, FSAVE, FDEF”
    31 •       “T”
    32 •       “LOOP”
     22 * “HI”
     23 * “C”, “O”
     24 * “M <optional position parameter>”
     25 * “HOME”
     26 * “IC <optional step size parameter>”, “IO <optional step size parameter>”
     27 * “TC”, “TO”
     28 * “FSET <property> <value>”
     29 * “FGET <property>”
     30 * “FLOAD, FSAVE, FDEF”
     31 * “T”
     32 * “LOOP”
    3333
    3434The list of properties available on 280 hands is a subset of Puck 2 hand properties and virtual properties such as the ones that contain !RealTime variables.  Refer to the !RealTime section for more information on !RealTime properties.  The API contains documentation for 262 and 280 hands in separate source code files for each hand.  The documentation is easily accessible through the supervisory tab of the !BarrettHand Control GUI.  The programmer no longer needs to flip through this manual to find hand properties and their purpose, descriptions, notes, etc.  The property list that each hand contains provides several useful attributes such as being read-only, global, and also a range of values that is used to validate inputs to some commands.