| 1 | = WAM Accuracy and Repeatability Study = |
| 2 | |
| 3 | == Repeatability Test == |
| 4 | |
| 5 | {{{ |
| 6 | #!div class="center" align="center" |
| 7 | [[Image(htdocs:wam/accuracy/wam_moving_towards.jpg)]] |
| 8 | |
| 9 | '''Figure 1: WAM arm moving towards dial indicator''' |
| 10 | }}} |
| 11 | |
| 12 | {{{ |
| 13 | #!div class="center" align="center" |
| 14 | [[Image(htdocs:wam/accuracy/wam_touching.jpg)]] |
| 15 | |
| 16 | '''Figure 2: WAM arm touching dial indicator''' |
| 17 | }}} |
| 18 | |
| 19 | {{{ |
| 20 | #!div class="center" align="center" |
| 21 | [[Image(htdocs:wam/accuracy/encoder_scale.jpg)]] |
| 22 | |
| 23 | '''Figure 3: Motor encoder scale''' |
| 24 | }}} |
| 25 | |
| 26 | Encoder resolution: 40,000 counts/rev |
| 27 | Motor resolution: 0.009 deg/count |
| 28 | Joint 1 transmission ratio: 30:1 |
| 29 | Ideal joint resolution: .0003 deg/count |
| 30 | Approximate moment arm: 1 m |
| 31 | Ideal repeatability: 0.005 mm |
| 32 | |
| 33 | === Repeatability Data === |
| 34 | |
| 35 | {{{ |
| 36 | #!div class="center" align="center" |
| 37 | [[Image(htdocs:wam/accuracy/repeatability_data.png)]] |
| 38 | }}} |
| 39 | |
| 40 | == Accuracy Test == |
| 41 | |
| 42 | {{{ |
| 43 | #!div class="center" align="center" |
| 44 | [[Image(htdocs:wam/accuracy/single_link_pen.jpg)]] |
| 45 | |
| 46 | '''Figure 4: WAM - single link''' |
| 47 | }}} |
| 48 | |
| 49 | {{{ |
| 50 | #!div class="center" align="center" |
| 51 | [[Image(htdocs:wam/accuracy/single_link_closeup.jpg)]] |
| 52 | |
| 53 | '''Figure 5: Closeup of single link WAM''' |
| 54 | }}} |
| 55 | |
| 56 | {{{ |
| 57 | #!div class="center" align="center" |
| 58 | [[Image(htdocs:wam/accuracy/dual_link.jpg)]] |
| 59 | |
| 60 | '''Figure 6: WAM - dual link''' |
| 61 | }}} |
| 62 | |
| 63 | === Notes regarding accuracy data: === |
| 64 | It is important to note that the repeatability data is a better measure for calibrated accuracy than is uncalibrated accuracy. Uncalibrated accuracy was measured as shown in the figures to the right. A pen attached to the outer link was used to plot points on paper taped to the floor and the WAM base was secured to the floor. |
| 65 | |
| 66 | Potential sources of measurement error include: |
| 67 | * the floor was assumed to be flat |
| 68 | * physical measurement error with rulers & T-squares |
| 69 | * physical measurement of WAM origin difficult to measure accurately |
| 70 | |
| 71 | Sources of system error (calibration error) include: |
| 72 | * transmission ratio errors |
| 73 | * tolerance stack-up of parts |
| 74 | * tool location measurement (tip of pen) |
| 75 | |
| 76 | === Accuracy Data === |
| 77 | |
| 78 | {{{ |
| 79 | #!div class="center" align="center" |
| 80 | [[Image(htdocs:wam/accuracy/accuracy_vs_reach.png)]] |
| 81 | }}} |
| 82 | |
| 83 | {{{ |
| 84 | #!div class="center" align="center" |
| 85 | [[Image(htdocs:wam/accuracy/graphs.png)]] |
| 86 | }}} |
| 87 | |