19 | | The necessary switches are located on the safety board. Un-clip the four outer cover clips (two on each side) and remove the single screw on the top-left of the back cover with a 4mm hex wrench. There are 4 switches located along the side of the board (see attachment:safetyboard_ae_switches.jpg); switches C and D control the CAN routing. Use the following table to select the correct positions: |
| 19 | There are two revisions of Type E safety boards, AE-02 and AE-03. The AE-02 model supports the older BH8-262 grasper and contains more parts than the AE-03 model, which supports the BH8-280 grasper. These are shown below for comparison. |
| 20 | |
| 21 | {{{ |
| 22 | #!div class="center" align="center" |
| 23 | || [[Image(htdocs:wam/AE-02.jpg)]] || [[Image(htdocs:wam/AE-03.jpg)]] || |
| 24 | || '''Safety Board Rev.AE-02 (supports BH8-262)''' || '''Safety Board Rev.AE-03 (supports BH8-280)''' || |
| 25 | }}} |
| 26 | |
| 27 | To switch between internal and external control, unclip the four outer cover clips (two on each side) and remove the single screw on the top-left of the back cover with a 4mm hex wrench. Switches C and D control the CAN routing. Use the following table to select the correct positions (they are the same for both revisions of the board). |
27 | | '''Note:''' It is possible to control two WAMs from one PC-104 internal PC. You will need a special cable to connect the WAMs via the external CAN connectors on the back of each system (contact Barrett for information). Configure the slave system for External control. Configure the master system for Internal control. In addition, you will need to toggle an additional switch on the master system underneath the safety board cover; switch E is normally OUT -- on the master system, you will need to switch this to IN. See attachment:safetyboard_ae_under_switches.jpg. |
28 | | |
29 | | '''NOTE:''' The above is not entirely correct. Switch E does not get stuffed consistently in the same orientation. We will need to include documentation to show the user which way is ON (connected, for special case) and which is OFF (disconnected, default). |
| 35 | '''Note:''' It is possible to control two WAMs from one PC-104 internal PC. You will need a special cable to connect the WAMs via the external CAN connectors on the back of each system (contact Barrett for information). Configure the slave system for External control. Configure the master system for Internal control. In addition, you will need to toggle switch E in the master system underneath the safety board cover. Switch E is normally OUT, switch this to IN on the master system. Occasionally switch E is not stuffed correctly on the safety board. The default position is OFF, which is usually OUT. If switch E on your safety board is IN to begin with, your switch is backwards and you must reverse the switch E positions noted above. This does not apply to the other switches. |